TRIPLE E TRADING CO., LTD.
Fluke 1577 Insulation Multimeter MegOhm Meter Combo
฿21860.00
Fluke 1577 Insulation Multimeter MegOhm Meter Combo
เหลือ 99 ชิ้น
ซื้อเลย
หยิบลงตะกร้า
  • หมวดหมู่ : MegOhm Meters
  • รหัสสินค้า : 006688

รายละเอียดสินค้า Fluke 1577 Insulation Multimeter MegOhm Meter Combo

 

Specifications
Specifications
Voltage DC
Maximum Voltage: 1000 V
Accuracy: 1577: ±(0.2%+2) 
1587: ±(0.09%+2
Maximum Resolution: 0.001V
Voltage AC
Maximum Voltage: 1000 V
Accuracy: 157 1577: ±(2%+3) 
1587: ±(2%+3)
AC Bandwidth: 1587: 5kHz*
*with low pass filter; 3db @ 800 Hz
Maximum Resolution: 0.1mV
Current DC
Maximum Amps: 400mA
Amps Accuracy: 1577: ±(1.0%+2) 
1587: ±(0.2%+2)
Maximum Resolution: 0.01 mA
Current AC
Maximum Amps: 400mA
Amps Accuracy: 11577: ±(2.0%+2)* 
1587: ±(1.5%+2)* 
* 1kHz bandwidth
Maximum Resolution: 0.01 mA
Resistance
Maximum Resistance: 50 MΩ
Accuracy: 1577: ±(1.2%+2) 
1587: ±(0.9%+2)
Maximum Resolution: 0.1Ω
Capacitance(1587 only
Maximum Capacitance: 9,999 µF
Accuracy: ±(1.2%+2)
Maximum Resolution: 1 nF
Frequency (1587 only)
Maximum Frequency: 100 kHz
Accuracy: ±(0.1%+1)
Maximum Resolution: 0.01 Hz
Temperature Measurement (1587 only)
-40.0 °C to 537 °C 
-40.0 °F to 998 °F 
excluding probe
Diode Test (1587 only)
Range: 6 V
Resolution: 1 mV
Accuracy: ±(2 % + 1)
Insulation Test
Minimum Test Current @ 1kΩ/V:
1mA
Test Voltages:
1577: 500, 1000 V
1587: 50, 100, 250, 500, 1000 V
Maximum Resistance per Test Voltage:
50V:  
100V:  
250V:  
500V:  
1000V: 1577: 600 MΩ 
1587: 2 GΩ
Maximum Resolution per Test Voltage:
50V: 0.01 MΩ
100V: 0.01 MΩ
250V: 0.1 MΩ
500V: 0.1 MΩ
1000V: 0.1 MΩ
Accuracy per Test Voltage:
50V: ±(3 % + 5)
100V: ±(3 % + 5)
250V: ±(1.5 % + 5)
500V: 1577: ±(2.0 % + 5) 
1587: ±(1.5 % + 5)
1000V: 1577: ±(2.0 % + 5)
1587: ±(1.5 % + 5) to 600 MΩ, ±(10 % + 3) above 600 MΩ
Environmental Specifications
Operating temperature
–20 °C to +55 °C
Storage temperature
-40°C to +60°C
Humidity (Without Condensation)
0% - 95% (10 °C – 30 °C) 
0% - 75% (30 °C – 40 °C) 
0% - 40% (40 °C – 55 °C)
Operating Altitude
2000 m
Safety Specifications
Overvoltage category
Complies with ANSI/ISA 82.02.01 (61010-1) 2004, CAN/CSA-C22.2 NO. 61010-1-04, and IEC/EN 61010-1 2nd Edition for measurement CAT III 1000 V and CAT IV 600 VC
Agency Approvals
2000 m CAT III 1000 V, CAT IV 600 V; 3000 m CAT II 1000 V, CAT III 600 V
Mechanical & General Specifications
Size
203 x 100 x 50 mm (with holster)
Weight
624 g
Warranty
3 years
Battery life Alkaline
Meter use: 1000 hours
Insulation test use: Meter can perform at least 1000 insulation tests with fresh alkaline batteries at room temperature. These are standard tests of 1000 V into 1 MΩ with a duty cycle of 5 seconds on and 25 seconds off.
IP Rating
IP40