Model |
CZ-H32 |
CZ-H35S |
CZ-H37S |
|||
Type |
Adjustable spot |
Luster cancel |
Luster-cancel, small beam spot |
|||
Detection range |
50 to 95 mm 1.97" to 3.74" |
28 to 52 mm 1.10" to 2.05" |
11 to 20 mm 0.43" to 0.79" |
|||
Smallest spot diameter |
Small: 3 mm 0.12"dia. |
4.5 mm 0.18"dia. at reference |
1 mm 0.04"dia. at reference |
|||
Light source |
Red LED (665 nm)/Green LED (520 nm)/Blue LED (465 nm) |
|||||
Minimum bend radius of fiber |
25 mm 0.98" |
15 mm 0.59" |
||||
Ambient light |
Incandescent lamp: 10000 lux max., Sunlight: 20000 lux max. |
|||||
Ambient temperature |
-10 to +55°C (14 to 131°F), No condensation |
|||||
Vibration resistance |
10 to 55 Hz, 1.5 mm 0.06"double amplitude in X, Y, and Z directions, 2 hours respectively |
|||||
Enclosure rating |
IP40 |
|||||
Material |
Housing |
Fiberglass reinforced plastic |
||||
Lens cover |
Polyarylate |
Triacetate, Polyarylate (Metal section: TYPE 304 stainless steel) |
||||
Weight (with 2-m 6.6' cable) |
Approx. 40 g |
Approx. 45 g |
||||
*1 Reference distance: 65 mm 2.56” for Small, 60 mm 2.36” for Medium, and 50 mm 1.97” for Large |
Model |
CZ-H52 |
|||
Type |
Fluorescence detection UV |
|||
Detection range |
25 to 55 mm 0.98" to 2.17" |
|||
Smallest spot diameter |
10 mm 0.39" dia. at reference |
|||
Light source |
UV (ultraviolet) LED (375 nm) *1 |
|||
Receivable wavelength (Receiver) |
425 to 550 nm |
|||
Minimum bend radius of fi ber |
— |
|||
Ambient light |
Incandescent lamp: 10,000 lux max., |
|||
Ambient temperature |
-10 to +55°C (14 to 131°F), No condensation |
|||
Vibration resistance |
10 to 55 Hz, 1.5 mm 0.06” double amplitude in X, Y, and Z |
|||
Enclosure rating |
IP40 |
|||
Material |
Housing |
Fiberglass reinforced plastic |
||
Lens cover |
Glass |
|||
Weight (with 2-m 6.6' cable) |
Approx. 40 g |
|||
*1 The CZ-H52 emits ultraviolet light from the transmitter. Do not directly look at the light |
Model |
CZ-H72 |
|||
Type |
Luster detection (Adjustable beam spot) |
|||
Detection range |
15 mm 0.59" (Center)*1 |
|||
Smallest spot diameter |
Small: 3 mm 0.12" dia. |
|||
Light source |
Red LED (665 nm) |
|||
Minimum bend radius of fi ber |
25 mm 0.98" |
|||
Ambient light |
Incandescent lamp: 10,000 lux max., |
|||
Ambient temperature |
-10 to +55°C (14 to 131°F), No condensation |
|||
Vibration resistance |
10 to 55 Hz, 1.5 mm 0.06" double amplitude in X, Y, |
|||
Enclosure rating |
IP40 |
|||
Material |
Housing |
Fiberglass reinforced plastic |
||
Lens cover |
Glass |
|||
Weight (with 2-m 6.6' cable) |
Approx. 50 g |
|||
*1 Small beam spot: 15 ±3 mm 0.59" ±0.12", Large beam spot: 15 ±5 mm 0.59" ±0.20" |
Model |
NPN |
CZ-V21A*2 |
CZ-V22A*2 |
||
PNP |
CZ-V21AP*2 |
CZ-V22AP*2 |
|||
Unit type (Main/expansion) |
Main unit |
Expansion unit |
|||
Response time |
200 μs (HIGH SPEED)/1 ms (FINE)/4 ms (TURBO)/8 ms (SUPER) |
||||
Control output |
NPN |
NPN open-collector x 4 channels, 40 VDC max., Up to 100 mA for one output, Up to 200 mA in total of 4 outputs, Residual voltage: 1.0 V max. |
|||
PNP |
PNP open-collector x 4 channels, 30 VDC max., Up to 100 mA for one output, Up to 200 mA in total of 4 outputs, Residual voltage: 1.0 V max. |
||||
Protection circuit |
Reverse-polarity protection, overcurrent protection, surge absorber |
||||
External calibration input |
Input time: 20 ms min. |
||||
External bank switch input (C/C+I mode), |
|||||
Timer function |
Timer OFF/OFF-delay/ON-delay/One-shot, Timer time: 1 to 1000 ms adjustable (for each bank respectively) |
||||
Power supply |
24 VDC, Ripple (P-P): 10% max. |
||||
Current consumption. |
Normal mode: 1.5 W (62.5 mA max.), Eco-mode: 1 W (42.0 mA max.) |
||||
Ambient temperature *1 |
-10 to +55°C (14 to 131°F), No condensation |
||||
Vibration resistance |
10 to 55 Hz, 1.5 mm 0.06" double-amplitude in X, Y, and Z directions, 2 hours respectively |
||||
Material |
Housing, cover: Polycarbonate |
||||
Weight (with 2-m 6.6' cable) |
Approx. 110 g |
Approx. 100 g |
|||
*1 When several units are connected, the acceptable ambient temperature varies depending on the conditions given below. To connect several units, be sure to mount them to a DIN rail and to limit the output |
This website uses cookies (Learn more) and has a privacy policy (Learn more).