Model |
FU-L52Z |
|||
Detection system |
Thrubeam |
|||
Optical axis height |
15mm |
|||
Optical axis diameter (mm) |
Object with a diameter of 1.13 |
|||
Standard detection object (mm) |
||||
Beam emitting direction |
Top |
|||
Cable length |
2 m free-cut |
|||
Fiber diameter |
2.2 |
|||
Operating ambient temperature |
-40 to +50°C |
|||
Fiber allowable bend radius (mm inch) |
R2 Tough-Flex |
|||
Detection distance (mm inch)when the FS-N10 Series is used |
MEGA |
2200 |
||
MEGA |
ULTRA |
1700 |
||
SUPER |
1000 |
|||
TURBO |
760 |
|||
FINE |
450 |
|||
HIGH SPEED |
290 |
|||
When using the FS-V30 Series |
When APC is on |
MEGA |
1170 |
|
ULTRA |
990 |
|||
SUPER |
540 |
|||
TURBO |
420 |
|||
FINE |
210 |
|||
HIGH SPEED |
125 |
|||
When APC is off |
MEGA |
1530 |
||
ULTRA |
1170 |
|||
SUPER |
680 |
|||
TURBO |
540 |
|||
FINE |
270 |
|||
HIGH SPEED |
180 |
|||
Minimum detectable object (mm)*1 |
Object with a diameter of 0.005 |
|||
Weight |
App. 30g |
|||
*1 The minimum detectable object is the value when the detecting distance and sensitivity have been set to their optimal state. |