Model |
IA-100 |
|||
Reference distance |
100 mm |
|||
Measurement range |
75 mm to 130 mm |
|||
Light source |
Type |
Red semiconductor laser, wavelength: 655 nm (visible light) |
||
Laser class |
Class II (FDA (CDRH) Part1040.10) |
|||
Output |
560 μW |
|||
Spot diameter (at standard distance) |
Approx. 400 × 1350 μm |
|||
Linearity *1 |
±0.15% of F.S. (F.S.=±20 mm, |
|||
Repeatability *2 |
10 μm |
|||
Sampling rate |
0.33/1/2/5 ms (4 levels available) |
|||
Operation status indicators |
Laser warning: Green LED, Analogue output: Red LED, Measurement centre: Green LED |
|||
Temperature characteristics |
0.06% of F.S./°C (F.S.=±20 mm , |
|||
Environmental |
Enclosure rating |
IP67 |
||
Ambient light *3 |
Incandescent lamp: 7500 lux |
|||
Ambient temperature |
-10 to +50°C (No condensation or freezing) |
|||
Relative humidity |
35 to 85% RH (No condensation) |
|||
Vibration |
10 to 55 Hz 1.5 mm double amplitude, in the X, Y and Z directions, 2 hours respectively |
|||
Material |
Housing material: PBT Metal parts: SUS304 Packing: NBR Lens cover: Glass Cable: PVC |
|||
Weight (including cable) |
Approx. 130g |
|||
*1 Value when measuring the KEYENCE standard target (white diffuse object). |