รายละเอียดสินค้า Fluke 87-V Ex Intrinsically Safe True RMS Multimeter
|
General Specifications |
|
Voltage DC |
|
Maximum voltage: |
1000 V |
|
Accuracy: |
± (0.05 % + 1) |
|
Maximum resolution: |
10 μV |
|
|
Voltage AC |
|
Maximum voltage: |
1000 V |
|
Accuracy: |
± (0.7 % + 2) True-rms |
|
AC bandwidth: |
20 kHz |
|
Maximum resolution: |
10 μV |
|
|
Current DC |
|
Maximum amps: |
10 A (20 A for 30 seconds maximum) |
|
Amps accuracy: |
± (0.2 % + 2) |
|
Maximum resolution: |
0.01 μA |
|
|
Current AC |
|
Maximum amps: |
10 A (20 A for 30 seconds maximum) |
|
Amps accuracy: |
± (1.0 % + 2) |
|
Maximum resolution: |
True-rms 0.01 μA |
|
|
Resistance |
|
Maximum resistance: |
50 MΩ |
|
Accuracy: |
± (0.2 % + 1) |
|
Maximum resolution: |
0.01 Ω |
|
|
Capacitance |
|
Maximum capacitance: |
9,999 μF |
|
Accuracy: |
± (1 % + 2) |
|
Maximum resolution: |
0.001 nF |
|
|
Frequency |
|
Maximum frequency: |
200 kHz |
|
Accuracy: |
± (0.005 % + 1) |
|
Maximum resolution: |
0.001 Hz |
|
|
Duty Cycle |
|
Maximum duty cycle: |
99.90 % |
|
Accuracy: |
± (0.2 % per khz +0.1 %) |
|
Maximum resolution: |
0.10 % |
|
|
Temperature |
|
Range: |
-200.0 °C to 1090 °C (-328 °F to 1994 °F) excluding probe |
|
|
80BK Temperature Probe |
|
Range: |
-40.0 °C to 260 °C (-40 °F to 500 °F) |
|
Accuracy: |
2.2 °C or 2 % whichever is greater |
|
|
Conductance |
|
Maximum conductance: |
60.00 nS |
|
Accuracy: |
± (1.0 % + 10) |
|
Maximum resolution: |
0.001 nS |
|
|
Diode |
|
Range: |
3 V |
|
Resolution: |
1 mV |
|
Accuracy: |
± (2 % + 1) |
|
|
Duty Cycle Range |
Accuracy: Within ± (0.2 % per kHz + 0.1 %) |
|
Measurements restriction in Ex-hazardous area |
|
Voltage: |
65 V |
|
Current: |
5 A |
|
|
Environmental Specifications |
|
Operating Temperature |
-20 °C to +50 °C |
|
Storage Temperature |
-40 °C to +60 °C |
|
Humidity (Without Condensation) |
0 % to 80 % (0 °C to 35 °C) 0 % to 70 % (35 °C to 50 °C) |
|
Operating Altitude |
2000 m |
|
Safety Specifications |
|
Overvoltage category |
EN 61010-1 to 1000 V CAT III, 600 V CAT IV |
|
Agency Approvals |
CSA, TÜV |
|
ATEX certification |
Ex II 2 G EEx ia IIC T4 |
|
Agency Approvals |
ZELM 05 ATEX 0274 |
|
Mechanical & General Specifications |
|
Size |
201 x 98 x 52 mm (with holster) |
|
Weight |
12,5 oz. (355 kg) with holster |
|
Display (Digital) |
6000 counts updates 4/sec. 19,999 counts in high-resolution mod |
|
Display (Analog) |
32 segments, updates 40/sec. |
|
Warranty |
1 year |
|
Battery Life |
~400 hours typical without backlight |
|
Shock |
1 Meter drop per IEC 61010-1:2001 |
|
Vibration |
Per MIL-PRF-28800 for a Class 2 instrument |