| Specifications | |||||||
| Temperature |
|
||||||
| Relative humidity |
0 °C to 30 °C (32 °F to 86 °F): 90 % 30 °C to 40 °C (86 °F to 104 °F): 75 % 40 °C to 50 °C (104 °F to 122 °F): 45 % |
||||||
| Altitude |
|
||||||
| Battery type/life | AAA (2); 40 hours | ||||||
| Shock, vibration | Sinusoidal vibration per MIL-PRF-28800F for a Class 2 instrument | ||||||
| Safety |
ISA-82.02.01 (IEC 61010-1 Mod) Second Edition, CAN/CSA-C22.2 No. 61010-1 Second Edition, IEC 61010 - 1 to 1000 V CAT III/600 V CAT IV Compliance to NFPA 70E* |
||||||
| AC Bandwidth | 45 Hz to 66 Hz | ||||||
| Maximum working voltage | 1000 V ac/dc | ||||||
| Maximum measurable voltage | 600 V ac/dc | ||||||
| Duty cycle |
Indefinitely for voltages up to 240 V For voltages between 240 V and 600 V the duty cycle is 30 s on / 300 s off For voltages above 240 V the tester must connect to a voltage source only for a MAXIMUM of 30 s and then disconnect for a MINIMUM of 300 s |
||||||
| Voltage hazard LED | LEDs turn on at voltages > 30 V ac/dc ± 35 % | ||||||
| LED voltage indication levels | 12 V, 24 V, 48 V, 120 V, 208 V, 240 V, 277 V, 480 V, 600 V | ||||||
| LED voltage indication levels for Canadian version | 12 V, 24 V, 48 V, 120 V, 208 V, 240 V, 347 V, 480 V, 600 V | ||||||
| LEDs | LEDs turn on between 90 % and 100 % of the indicated voltage on the LED, except for the 12 V LED which turns on between 50 % and 100 % | ||||||
| LCD Accuracy on T+PRO only |
|
||||||
| LCD Resolution |
0.1 V for voltages < 50 V, 1 V for voltages ≥ 50 V 0.01 kΩ for resistance measurement (For T+PRO Only) |
||||||
| GFCI Test current | 100 V - 150 V @ 6 mA - 9 mA ac, 150 V - 240 V < 12 mA | ||||||
| Standard input test current | < 5 mA | ||||||
| Size (HxWxL) | 1.3 in x 2.15 in x 7.6 in (3.3 cm x 5.46 cm x 19.3 cm ) | ||||||
| Weight | 9.9 oz (0.28 kg) | ||||||