Trigger System
Main Trigger Modes Auto, Normal and Single.
Trigger Coupling DC, HF reject (attenuates >50 kHz), LF reject (attenuates <50 kHz), noise reject (reduces sensitivity).
Trigger Holdoff Range 20 ns to 8 s.
Sensitivity
Internal DC Coupled 0.4 div DC to 50 MHz, increasing to 1 div at rated bandwidth.
External (Auxiliary Input) 200 mV from DC to 50 MHz increasing to 500 mV at 250 MHz.
Trigger Level Range
Any Channel ±8 divisions from center of screen.
External (auxiliary input) ±8V.
Trigger Modes
Edge Positive or negative slope on any channel or front panel auxiliary input. Coupling includes DC, HF reject, LF reject and noise reject.
Sequence (B-trigger) Trigger Delay by Time – 4 ns to 8 s. Or Trigger Delay by Events – 1 to 9,999,999 events.
Pulse Width Trigger on width of positive or negative pulses that are >, <, = or ≠ a specified period of time.
Runt Trigger on a pulse that crosses one threshold but fails to cross a second threshold before crossing the first again.
Logic Trigger when any logical pattern of channels goes false or stays true for specified period of time. Any input can be used as a clock to look for the pattern on a clock edge. Pattern (AND, OR, NAND, NOR) specified for all analog and digital input channels defined as High, Low or Don’t Care.
Setup and Hold Trigger on violations of both setup time and hold time between clock and data present on any of the input channels. Rise/Fall Time Trigger on pulse edge rates that are faster or slower than specified. Slope may be positive, negative or either.
Video Trigger on line number, all lines, odd, even or all fields on NTSC, PAL and SECAM video signals.
Extended Video (optional) Trigger on 480p/60, 576p/50, 720p/30, 720p/50, 720p/60, 875i/60, 1080i/50, 1080i/60, 1080p/24, 1080p/24sF, 1080p/25, 1080p/30, 1080p/50, 1080p/60 and custom bi-level and tri-level sync video standards.
I 2C (optional) Trigger on Start, Repeated Start, Stop, Missing ACK, Address (7 or 10 bit), Data or Address and Data on I 2C buses up to 3.4 Mb/s.
SPI (optional) Trigger on SS, MOSI, MISO or MOSI and MISO on SPI buses up to 50.0 Mb/s (not available on DPO4032).
CAN (optional) Trigger on Start of Frame, Frame Type (data, remote, error, overload), Identifier (standard or extended), Data, Identifier and Data, End of Frame or Missing ACK on CAN signals up to 1 Mb/s. Data can be further specified to trigger on ≤, <, =, >, ≥ or ≠ a specific data value. User-adjustable sample point is set to 50% by default.
RS-232/422/485/UART (optional) Trigger on Tx start bit, Rx start bit, Tx end of packet, Rx end of packet, Tx data, Rx data.
Parallel (available on MSO models only) Trigger on a parallel bus data value.
Acquisition Modes
Sample Acquires sampled values.
Peak Detect Captures glitches as narrow as 200 ps at all sweep speeds.
Averaging From 2 to 512 waveforms included in average.
Envelope Min-max envelope reflecting Peak Detect data over multiple acquisitions.
Hi Res Real-time boxcar averaging reduces random noise and increases vertical resolution. Roll Scrolls waveforms right to left across screen at sweep speeds slower than or equal to 40ms/div.
Waveform Measurements
Cursors Waveform and Screen.
Automatic Measurements 25, of which up to four can be displayed on screen at any one time. Measurements include Period, Frequency, Delay, Rise Time, Fall Time, Positive Duty Cycle, Negative Duty Cycle, Positive Pulse Width, Negative Pulse Width, Burst Width, Phase, Positive Overshoot, Negative Overshoot, Peak to Peak, Amplitude, High, Low, Max, Min, Mean, Cycle Mean, RMS, Cycle RMS, Area and Cycle Area.
Measurement Statistics Mean, Min, Max, Standard Deviation.
Reference Levels User-definable reference levels for automatic measurements can be specified in either percent or units.
Gating Isolate the specific occurrence within an acquisition to take measurements, using either the screen or waveform cursors.
Waveform Math
Arithmetic Add, subtract, multiply and divide waveforms.
Math Functions Integrate, Differentiate, FFT.
FFT Spectral magnitude. Set FFT Vertical Scale to Linear RMS or dBV RMS, and FFT Window to Rectangular, Hamming, Hanning or Blackman-Harris.
Advanced Math Define extensive algebraic expressions including analog waveforms, math functions, scalars, up to two user-adjustable variables and results of parametric measurements e.g., (Intg (Ch1-Mean(Ch1)) x 1.414 x VAR1).
Software
National Instruments SignalExpress Tektronix Edition A fully interactive measurement software environment optimized for the 4000 Series, enables you to instantly acquire, generate, analyze, compare, import and save measurement data and signals using an intuitive drag-and-drop user interface that does not require any programming. Standard 4000 Series support for acquiring, controlling, viewing and exporting your live signal data is permanently available through the software. The Professional version adds additional signal processing, advanced analysis, mixed signal, sweeping, limit testing and user-defined step capabilities and is available for a 30-day trial period standard with each instrument.
OpenChoice® Desktop Enables fast and easy communication between a Windows PC and the 4000 Series via USB or LAN. Transfer and save settings, waveforms, measurements and screen images.
IVI Driver Provides a standard instrument programming interface for common applications such as LabVIEW, LabWindows/CVI, Microsoft .NET and MATLAB.
Display Characteristics
Display Type 10.4 in. (264mm) liquid crystal TFT color display.
Display Resolution 1024 horizontal x 768 vertical pixels (XGA).
Waveform Styles Vectors, Dots, Variable Persistence, Infinite Persistence.
Graticules Full, Brid, Cross Hair, Frame, IRE and mV.
Format YT and simultaneous XY/YT.
Waveform Capture Rate Up to 35,000 wfms/sec.
Input/Output Ports
CompactFlash Drive Front panel access (Type 1) USB2.0 Full Speed Host Port – Supports USB mass storage devices, printers and keyboard. Two ports available on rear-panel and one on front-panel.
USB 2.0 High Speed Device Port Rear panel connector allows for control of oscilloscope via USBTMC or GPIB with a TEK-USB-488.
LAN Port RJ-45 connector, supports 10/100Base-T.
XGA Video Port DB-15 female connector, connect to show the oscilloscope display on an external monitor or projector.
Auxiliary Input Front panel BNC connector. Input Impedance 1 MΩ. Max input 250 VRMS with peaks ±400 V.
Probe Compensator Output Front panel pins.
Amplitude 2.5 V Frequency 1 kHz.
Trigger Out Rear-panel BNC connector, provides a positive polarity pulse when the oscilloscope triggers.
Kensington Lock Rear-panel security slot connects to standard Kensington lock.
Power Source
Power Source Voltage 100 to 240 V ±10%
Power Source Frequency 47 to 66 Hz (90 to 264 V), 360 to 440 Hz (100 to 132 V).
Power Consumption 250 W maximum.
Physical Characteristics
Height 229mm / 9in
Width 439mm / 17.3in
Depth 137mm / 5.4in
Net Weight 5kg / 11lbs
Shipping Weight 9.5kg / 22lbs
Rackmount Configuration 5U
Cooling Clearance 2 in. (51mm) required on left side and rear of instrument
General Characteristics
Operating Temperature 0 ºC to +50 ºC.
Non-operating Temperature -20 ºC to +60 ºC.
Operating Humidity High: 40 ºC to 50 ºC, 10% to 60% relative humidity.
Low: 0 ºC to 40 ºC, 10% to 90% relative humidity.
Non-operating Humidity High: 40 ºC to 60 ºC, 5% to 60% relative humidity.
Low: 0 ºC to 40 ºC, 5% to 90% relative humidity.
Operating Altitude 3,000 meters (9,843 feet).
Non-operating Altitude 12,000 meters (39,370 feet).
Operating Random Vibration 0.31 GRMS from 5 to 500 Hz, 10 minutes each axis, 3 axes, 30 minutes total.
Non-operating Random Vibration 2.46 GRMS from 5 to 500 Hz, 10 minutes each axis, 3 axes, 30 minutes total.
Electromagnetic Compatibility 89/336/EEC
Safety UL61010-1, Second Edition; CSA61010-1 Second Edition, EN61010-1:2001; IEC 61010-1:2001.
Vertical System Analog Channels
Input Channels 4
Analog Bandwidth (-3 dB)
5 mV/div to 1 V/div
200 MHz
Calculated Rise Time
5 mV/div (typical)
2.1 ps
Hardware Bandwidth Limits 20 MHz
Input Coupling AC, DC, GND
Input Impedance 1 MΩ 11.5 pF ±2 pF
Input Sensitivity 2 mV/div to 5 V/div
Vertical Resolution 8 bits
Max Input Voltage 300 VRMS with peaks <±450 V
DC Gain Accuracy ±3% for 10 mV/div to 5 V/div, ±4% for 2 mV/div to 5 mV/div
Offset Range
2 mV/div to 200 mV/div ±1 V
>200 mV/div to 5 V/div ±25 V
Channel-to-Channel Isolation ≥100:1 at ≤200 MHz Bandwidth is 20 MHz at 2 mV/div, all models
Vertical System Digital Channels
Input channels 16 Digital (D15 to D0)
Thresholds Threshold per set of 8 channels
Threshold Selections TTL, CMOS, ECL, PECL, User Defined
User-defined Threshold Range ±20 V
Maximum Input Voltage ±40 V
Threshold Accuracy ±(100 mV + 3% of threshold setting)
Input Dynamic Range 80 Vpk-pk (threshold setting dependent)
Minimum Voltage Swing 500 mV
Input Impedance 101 kΩ
Probe Loading 3 pF
Vertical Resolution 1 bit
Horizontal System Analog Channels
Maximum Sample Rate
(all channels)
1 GS/s
Minimum Peak Detect
Pulse Width
3.5 ns
Maximum Record Length
(all channels)
1 M points
Maximum Duration at Highest Sample Rate (all channels) 1 ms
Timebase Range 2 ns to 100 s
Timebase Delay Time Range -10 div to 5000 s
Channel-to-Channel
Deskew Range
±100ns
Timebase Accuracy ±25 ppm