บริษัท ทริปเปิ้ล อี เทรดดิ้ง จำกัด

Fluke Ti9 Thermal Imager 9Hz

฿92390.00
Fluke Ti9 Thermal imaging camera w/ 20 mm lens; AC power supply/battery charger (including mains adapters); SD memory
เหลือ 0 ชิ้น
ซื้อเลย
หยิบลงตะกร้า
  • หมวดหมู่ : Thermal Imaging
  • รหัสสินค้า : 006989

รายละเอียดสินค้า Fluke Ti9 Thermal Imager 9Hz

 

Temperature
Temperature measurement range (not calibrated below -10 °C) -20 °C to +250 °C (-4 °F to + 482 °F)
Accuracy ± 5 °C or 5 % (whichever is greater)
Imaging Performance
Field of view 23° x 17°
Spatial resolution (IFOV) 2.5 mRad
Minimum focus distance Thermal lens: 15 cm (6 in)
Focus Manual
Image frequency 9 Hz refresh rate
Detector type 160 X 120 focal plane array, uncooled microbolometer
Infrared lens type 20 mm F = 0.8 lens
Thermal sensitivity (NETD) ≤ 0.2 °C at 30 °C (200 mK)
Infrared spectral band 7.5 μm to 14 μm
Image Presentation
Palettes Ironbow, blue-red, high contrast, grey
Level and span Smooth auto-scaling and manual scaling of level and span
Minimum span (in manual mode) 5 °C (9 °F)
Minimum span (in auto mode) 10 °C (18 °F)
Image and Data Storage
Storage medium SD memory card (2 GB memory card will store at least 1200 fully radiometric (.is2) IR or 3000 basic (.bmp) IR images)
File formats Non-radiometric (.bmp) or fully-radiometric (.is2)
No analysis software required for non-radiometric (.bmp) files
Export file formats w/SmartView® software JPEG, BMP, GIF, PNG, TIFF, WMF, EXIF, and EMF
General Specifications
Temperature -Operating: -10 °C to 50 °C (14 °F to 122 °F)
Temperature - Storage: -20 °C to +50 °C (-4 °F to 122 °F) without batteries
Display 9.1 cm (3.6 in) diagonal landscape color VGA (640 x 480) LCD with backlight (selectable bright or auto)
Controls and adjustments
  • User selectable temperature scale (°C/°F)
  • Language selection
  • Time/Date set
Software SmartView® full analysis and reporting software included
Battery: Internal rechargeable battery pack (included)
Battery life: Three to four hours continuous use (assumes 50 % brightness of LCD)
Battery charge time using ac adapter/charger and dc car charger: Two hours for full charge
AC operation/charging AC adapter/charger (110 Vac to 220 Vac, 50 Hz to 60 Hz). Charges battery while imager is operating. Universal ac mains adapters included.
Power saving Sleep mode activated after 5 minutes of inactivity, automatic power off after 20 minutes of inactivity
Safety standards CE Directive: IEC/EN 61010-1 2nd Edition Pollution Degree 2
Electromagnetic compatibility
  • EMC directive: EN61326-1
  • C-Tick: IEC/EN 61326
  • US FCC: CFR 47, Part 15 Class A
Vibration 2 G, IEC 68-2-29
Shock 25 G, IEC 68-2-29 {2 m (6.5 ft) drop, 5 sides}
Dimensions (HxWxL) 0.27 m x 0.13 m x 0.15 m (10.5 in x 5 in x 6 in)
Weight 1.2 kg (2.65 lb)
IP rating IP54
Warranty Two-years
Calibration cycle Two-years (assumes normal operation and normal aging)
Supported languages English, Italian, German, Spanish, French, Russian, Portuguese, Swedish, Turkish, Czech, Polish, Finnish, Simplified Chinese, Traditional Chinese, Korean, and Japanese