24VAC 24VDC 100/110/120VAC 200/220/240VAC
| Accuracy of operating time | +/- 0.3% +/- 0.05 s (The values are based on the set value.) |
|---|---|
| Setting error | +/- 0.5% +/- 0.05 s (The values are based on the set value.) |
| Influence of voltage | +/- 0.3% +/- 0.05 s (The values are based on the set value.) |
| Influence of temperature | +/- 0.3% +/- 0.05 s (The values are based on the set value.) |
| Insulation resistance |
100 MOhm min. (at 500 VDC) between current-carrying terminals and exposed non-curernt-carrying metal parts, between control output terminals and operating circuit, between non-continuous contacts |
| Dielectric strength |
between current-carrying metal parts and non-curernt-carrying metal parts: 2000 VAC 50/60 Hz for 1 min between control output terminals and operating circuit: 2000 VAC 50/60 Hz for 1 min between non-continuous contacts: 1000 VAC 50/60 Hz for 1 min |
| Impulse withstand voltage |
between power terminals: 3 kV between current-carrying metal parts and exposed non-curernt-carrying metal parts: 4.5 kV |
| Noise immunity |
Between power terminals: +/- 2 kV Between input terminals: +/- 600 V Square-wave noise by noise simulator (Pulse width: 100 ns/1 us, Rise: 1-ns) |
| Vibration resistance (Destruction) | 10 to 55 Hz, 0.75 mm single amplitude in each 3 directions for 1 hour |
| Vibration resistance (Malfunction) | 10 to 55 Hz 0.5 mm single amplitude in each 3 directions for 10 min |
| Shock resistance (Destruction) | 1000 m/s**2, in each 6 directions (3 axes) 3 times |
| Shock resistance (Malfunction) | 100 m/s**2, in each 6 directions (3 axes) 3 times |
| Mechanical Life expectancy (relay output) | 10000000 operations min. (under no load at 1800 operations/h) |
| Electrical Life expectancy (relay output) | 100000 operations min. (3 A at 250 VAC resistive load at 1800 operations/h) |
| Degree of protection | IEC60529(JEM): Panel surface: IP40 |
| Applicable standard (UL) |
Standard No.: UL508 File number: E41515 |
| Applicable standard (CSA) |
Standard No.: CSA C22.2 No.14 File number: LR22310 |
| Applicable standard (LR) | Approved |
| Applicable standard (NK) | A-54-3 |
| Applicable standard (EC Directive (EMC Directive) ) |
EMI: EN61812-1 Emission Enclosure: EN55011 Group 1 class A Emission AC mains: EN55011 Group 1 class A EMS: EN61812-1 Immunity ESD: EN61000-4-2 (6 kV contact discharge (level 2), 8 kV air discharge (level 3)) RF-interference: EN61000-4-3 (10 V/m (Amplitude-modulated, 80 MHz to 1 GHz) (level 3), 10 V/m (Pulse-modulated, 900 MHz 5 MHz) (level 3)) Immunity Burst: EN61000-4-4 (2 kV power-line (level 3), 1 kV I/O signal-line (level 4)) Immunity Surge: EN61000-4-5 (1 kV line to lines (power and output lines) (level 3), 2 kV line to ground (power and output lines) (level 3)) |
| Mounting method | Flush mounting / Surface mounting |
| external connection method | 8-pin round socket |
| Case color | Light gray (Munsell 5Y7/1) |
| Accessory (sold separately) |
Soft Cover (Y92A-48D) Hard Cover (Y92A-48B) Flush Mounting Adapter (Y92F-30) Flush Mounting Adapter (Y92F-70) Flush Mounting Adapter (Y92F-71) |
| Weight | Approx. 110 g |