| Sensing method | Diffuse-reflective |
|---|---|
| Sensing distance |
30 mm to 700 mm (Standard mode, White paper) 30 mm to 1000 mm (High-resolution mode, White paper) 30 mm to 250 mm (Super-high-speed mode, White paper) |
| Spot size | 0.8mm Max. (At distance of 300mm Max.) |
| Light source | Semiconductor laser diode(red) (650nm) |
| Classification of laser |
IEC: CLASS 2 FDA: CLASS 2 JIS: CLASS 2 |
| Operation mode | Light-ON/Dark-ON selectable |
| Ambient illuminance | Incandescent lamp:3000 lux Max. |
| Ambient temperature |
Operating: -10 to 55 CEL Storage: -25 to 70 CEL (with no icing or condensation) |
| Ambient humidity |
Operating: 35 to 85 %RH Storage: 35 to 85 %RH (with no condensation) |
| Insulation resistance | 20 M OHM Min. at 500 VDC between charged parts and the case |
| Dielectric strength | 1000 VAC at 50/60 Hz for 1 minute between charged parts and the case |
| Vibration resistance | 10 to 150 Hz, 0.7-mm double amplitude for 1.5 hours each in X, Y, and Z directions |
| Shock resistance | 300m/s2 for 3 times each in X, Y, and Z directions |
| Degree of protection | IEC60529: IP40 |
| Applicable standard (EC Directive (Low Voltage Directive)) | EN60947-5-2 |
| Applicable standard (EC Directive (EMC Directive)) |
EMI: EN60947-5-2 Emission Enclosure: EN55011 Group 1 class A EMS: EN60947-5-2 Immunity ESD: IEC61000-4-2 Immunity RF-interference: IEC61000-4-3 Immunity Burst: IEC61000-4-4 CE marking: Equipped |
| Connection method | Pre-wired connector models(Special) (Cable length: 2 m) |
| Indicator | LD.ON indicator(green), Operation indicator(orange) |
| Weight (packed state) | approx. 85 g |
| Material (case) | ABS |
| Material (lens) | Methacrylate resin |
| Accessories | Instruction manual, Laser warning label (English) |
| Amplifier unit/sensor head of combination |
E3C-LDA** |