| Product outline | Simple fiber sensor (Bar display, Adjuster setting) |
|---|---|
| Sensing distance(Typical) |
E32-TC200: 0 to 800 mm E32-DC200: 0 to 300 mm |
| Light source | Red LED |
| Emission wave length | 625 nm |
| Power supply voltage | 12 to 24 VDC -10% to 10% (ripple(p-p) :10% Max.) |
| Current consumption | 40 mA Max. |
| Operation mode | Light-ON/Dark-ON selectable |
| Control output (Output type) | PNP open collector output |
| Control output (Load current) | 0 to 50 mA |
| Control output (Residual voltage) | (DC) 1 V Max. (load current:50mA Max.) |
| Protective circuit |
Surge suppressor Output short-cut protection Power supply reverse polarity protection |
| Response time | Operate 200 us Max., Reset 200 us Max. (More than 8 sensors connected: 350 us Max.) |
| Mutual interference prevention | 5 Units |
| Sensitivity setting | 8-revolution adjuster with indicator |
| Function | Timer function |
| Ambient illuminance | Incandescent lamp:10000 lux Max. Sunlight:20000 lux Max. |
| Ambient temperature (Operating) |
Groups of 1 to 3 Sensors:-25 to 55 CEL Groups of 4 to 11 Sensors:-25 to 50 CEL Groups of 12 to 16 Sensors:-25 to 45 CEL (with no icing or condensation) |
| Ambient temperature (Storage) |
-30 to 70 CEL (with no icing or condensation) |
| Ambient humidity |
Operating: 35 to 85 %RH Storage: 35 to 85 %RH (with no icing) |
| Insulation resistance | 20 M OHM Min. at 500 VDC between charged parts and the case |
| Dielectric strength | 1000 VAC at 50/60 Hz for 1 minute between charged parts and the case |
| Vibration resistance | 10 to 55 Hz1.5-mm double amplitude for 2 hours each in X, Y, and Z directions |
| Shock resistance | 500m/s2 for 3 times each in X, Y, and Z directions |
| Degree of protection | IEC60529: IP50 |
| Applicable standard (EC Directive (Low Voltage Directive)) | EN60947-5-2 |
| Applicable standard (EC Directive (EMC Directive)) |
EMI: EN60947-5-2 Emission Enclosure: EN55011 Group 1 classA EMS: EN60947-5-2 Immunity ESD: IEC61000-4-2 Immunity RF-interference: IEC61000-4-3 Immunity Conducted Disturbance: IEC61000-4-6 Immunity Burst: IEC61000-4-4 |
| Connection method | Pre-wired models (Cable length: 2 m) |
| Indicator | Operation indicator (Orange) |
| Weight (packed state) | Approx. 100 g |
| Material (case) | PBT |
| Material (cover) | Polycarbonate |
| Mounting | DIN rail or the mounting bracket type E39-L143 (sold separately) |
| Accessories |
Instruction manual |