Product outline Digital Fiber Sensor, 2-channel models, Connector models
Sensing distance(Typical) E32-TC200: 0 to 500 mm (Standard mode)
E32-DC200: 0 to 210 mm (Standard mode)
Light source Red LED
Emission wave length 635 nm
Power supply voltage 12 to 24 VDC -10% to 10% (ripple(p-p) :10% Max.)
Current consumption 45 mA Max.
Power consumption 1080 mW Max.
Operation mode Light-ON/Dark-ON selectable
Control output (Output type) NPN open collector output
Control output (Load current) 0 to 50 mA
Control output (Residual voltage) (DC) 1 V Max. (load current:50mA Max.)
Protective circuit Surge suppressor
Output short-cut protection
Power supply reverse polarity protection
Response time Standard mode: Operate 1 ms Max., Reset 1 ms Max.
High-resolution mode: Operate 4 ms Max., Reset 4 ms Max.
High-speed mode: Operate 450 us Max., Reset 450 us Max.
Super-high-speed mode (NPN): Operate 130 us Max., Reset 130 us Max. (When selected output is AND, OR, leading edge sync, falling edge sync, and differential output settings, The second channel output is 200 us for operation and reset respectively.)
Mutual interference prevention 9 Units(When power tuning is enabled: 5 Units)
Sensitivity setting Teaching or manual method
Function Zero reset
Initial reset
Power tuning
Auto power control
Timer function
Channel 2 output
Response speed selectable
Ambient illuminance Incandescent lamp:10000 lux Max. Sunlight:20000 lux Max.
Ambient temperature (Operating) Groups of 1 to 2 Sensors:-25 to 55 CEL
Groups of 3 to 10 Sensors:-25 to 50 CEL
Groups of 11 to 16 Sensors:-25 to 45 CEL
(with no icing or condensation)
Ambient temperature (Storage) -30 to 70 CEL
(with no icing or condensation)
Ambient humidity Operating: 35 to 85 %RH
Storage: 35 to 85 %RH
(with no icing)
Insulation resistance 20 M OHM Min. at 500 VDC between charged parts and the case
Dielectric strength 1000 VAC at 50/60 Hz for 1 minute between charged parts and the case
Vibration resistance 10 to 55 Hz1.5-mm double amplitude for 2 hours each in X, Y, and Z directions
Shock resistance 500m/s2 for 3 times each in X, Y, and Z directions
Degree of protection IEC60529: IP50
Applicable standard (EC Directive (Low Voltage Directive)) EN60947-5-2
Applicable standard (EC Directive (EMC Directive)) EMI: EN60947-5-2
Emission Enclosure: EN55011 Group 1 classA
EMS: EN60947-5-2
Immunity ESD: IEC61000-4-2
Immunity RF-interference: IEC61000-4-3
Immunity Conducted Disturbance: IEC61000-4-6
Immunity Burst: IEC61000-4-4
Connection method Connector models
Indicator Operation indicator (Orange), Digital display
Weight (packed state) Approx. 100 g
Material (case) PBT
Material (cover) Polycarbonate
Mounting DIN rail or the mounting bracket type E39-L143 (sold separately)
Applicable connector E3X-CN21, E3X-CN22
Accessories Instruction manual
 