| Product outline | Color sensing type Digital Fiber Sensor, Standard models |
|---|---|
| Sensing distance(Typical) |
E32-TC200: 0 to 32 mm (Standard mode (Translucent object)) E32-DC200: 0 to 10 mm (Standard mode (Standard card of 11 color)) |
| Light source | White LED |
| Emission wave length | 420 to 700 nm |
| Power supply voltage | 12 to 24 VDC -10% to 10% (ripple(p-p) :10% Max.) |
| Current consumption | 40 mA Max. (at 24V) |
| Power consumption | 960 mW Max. |
| Operation mode | Conformity output ON/Nonconformity output ON selectable |
| Control output (Output type) | NPN open collector output |
| Control output (Load current) | 0 to 50 mA |
| Control output (Residual voltage) | (DC) 2 V Max. (load current:50mA Max.) |
| Protective circuit |
Surge suppressor Output short-cut protection Output reverse polarity protection Power supply reverse polarity protection |
| Response time |
Standard mode: Operate 1 ms Max., Reset 1 ms Max. High-resolution mode: Operate 4 ms Max., Reset 4 ms Max. High-speed mode: Operate 300 us Max., Reset 300 us Max. Super-high-speed mode (NPN): Operate 60 us Max., Reset 60 us Max. |
| Mutual interference prevention | 10 Units(When the detection mode is selected during super-high-speed mode: Not function) |
| Sensitivity setting | Teaching or manual method |
| Function |
Zero reset Initial reset Timer function Key lock User reset |
| Ambient illuminance | Incandescent lamp:3000 lux Max. Sunlight:10000 lux Max. |
| Ambient temperature (Operating) |
Groups of 1 to 2 Sensors:-25 to 55 CEL Groups of 3 to 10 Sensors:-25 to 50 CEL Groups of 11 to 16 Sensors:-25 to 45 CEL (with no icing or condensation) |
| Ambient temperature (Storage) |
-30 to 70 CEL (with no icing or condensation) |
| Ambient humidity |
Operating: 35 to 85 %RH Storage: 35 to 85 %RH (with no icing) |
| Insulation resistance | 20 M OHM Min. at 500 VDC between charged parts and the case |
| Dielectric strength | 1000 VAC at 50/60 Hz for 1 minute between charged parts and the case |
| Vibration resistance | 10 to 55 Hz1.5-mm double amplitude for 2 hours each in X, Y, and Z directions |
| Shock resistance | 500m/s2 for 3 times each in X, Y, and Z directions |
| Degree of protection | IEC60529: IP50 |
| Applicable standard (EC Directive (Low Voltage Directive)) | EN60947-5-2 |
| Applicable standard (EC Directive (EMC Directive)) |
EMI: EN60947-5-2 Emission Enclosure: EN55011 Group 1 classA EMS: EN60947-5-2 Immunity ESD: IEC61000-4-2 Immunity RF-interference: IEC61000-4-3 Immunity Conducted Disturbance: IEC61000-4-6 Immunity Burst: IEC61000-4-4 |
| Connection method | Pre-wired models (Cable length: 2 m) |
| Indicator | Operation indicator (Orange), I mode indicator (Orange), Digital display |
| Weight (packed state) | Approx. 100 g |
| Material (case) | PBT |
| Material (cover) | Polycarbonate |
| Mounting | DIN rail or the mounting bracket type E39-L143 (sold separately) |
| Accessories |
Instruction manual |