Format | TL-W1R5MC1 form | TL-W3MC form □ | TL-W5MC form □ | |
Detection distance | 1.5mm ± 10% | 3mm ± 10% | 5mm ± 10% | |
Set distance | 0 ~ 1.2mm | 0 ~ 2.4mm | 0 ~ 4mm | |
Hysteresis | Less than 10% of sensing distance | |||
Object can be detected | Magnetic metal (detection distance is reduced. Nonmagnetic metal, see "Data Properties" in the catalog) | |||
Standard sensing object | 8 × 8 × 1mm iron | 12 × 12 × 1mm iron | 18 × 18 × 1mm iron | |
Frequency response | Above 1kHz | 600Hz or more | 500Hz or more | |
Supply voltage (operating voltage range) |
(Pp): 10% DC12 ~ 24V ripple (DC10 ~ 30V) | |||
Quiescent current | Less than 15mA (when DC24V, no load) | 10mA or less | ||
Control output | Switching capacity | NPN open collector 100mA (less than DC30V) |
NPN open collector 50mA or less when DC12V (less than DC30V) when less than 100mA DC24V (less than DC30V) |
|
Residual voltage | (At 100mA load current and the cord length 2m) below 1V. | (At 50mA load current and the cord length 2m) below 1V | ||
Indicator light | Detection indicator (red) | |||
Operating mode (when the sensing object approaching) |
NO |
Type C1: NO C2 type: NC |
||
For more information, see the time chart of "O Circuit Diagrams" catalog | ||||
Protection circuit | Reverse polarity protection, surge absorption | |||
Ambient temperature range | Operating and storage: -25 ~ +70 ℃ each (with no icing or condensation) * | |||
Ambient humidity range | Operating and storage: 35-95% RH (with no condensation) | |||
The effect of temperature | At +23 ℃, less than 10% ± of sensing distance in temperature range of -25 ~ +70 ℃ | |||
Effects of voltage |
Within ± 10% of rated supply voltage at the rated power supply voltage, the detection distance of less than 2.5% ± |
Rated in the range ± 20% of rated supply voltage at the power supply voltage, the detection distance of less than 2.5% ± |
||
Insulation resistance | Between charged parts and case (at DC500V mega) 50MΩ or more | |||
Withstand voltage | Between charged parts and the case, 000V 50/60Hz 1min AC1 | |||
Vibration (endurance) | 1.5mm X double amplitude 10 ~ 55Hz, Y, 2h each direction Z | |||
Shock (endurance) | 500 meters / s 2 times 3 X, Y, and Z directions |