| Shape / Structure | Touch switches |
|---|---|
| service life | General type |
| Operating mechanism | Electrostatic capacity type |
| Actuator | Free attachment |
| Electrical ratings | 12 to 24 VDC (10 to 30 VDC) ripple(p-p) 10% Max. |
| Current consumption / Power consumption | 17 mA Max. |
| Output signal | NPN (3-wire cable model) |
| Operating sensitivity |
Operating capacity: 30 pF Max. at the maximum sensitivity, 10 pF Max. at the minimum sensitivity. (The electrostatic capacity between the antenna and the ground) Operating resistance: 3 kOhm at the minimum sensitivity (The resistance between the antenna and the ground) The product is operated with an electrostatic capacity or a resistance. |
| Leakage current | 1mA Max.(at antenna) |
| Residual voltage | 2 V Max. (at a load of 200 mA) |
| Output current capacity | 200 mA Max. (resistive load) |
| Response time | 2 ms Max. |
| Load | General load |
| Indicator | LED (Light when operating) |
| Cable specifications |
VCT oil-resistant cable, 3 cores (Cable length: 3 m) Diameter: 4 mm dia. |
| Ambient temperature |
Operating: -25 to 70 CEL (with no icing or condensation) |
| Ambient humidity |
Operating: 35 to 95%RH (with no icing or condensation) |
| Temperature influence | Change of operating sensitivity at the minimum sensitivity in a temperature range from -25 to +70 DEG is 30 pF Max. of the operating capacity and 6 k Ohm Max. of the operating resistance. |
|---|---|
| Voltage influence | Change of operating sensitivity at the minimum sensitivity in a voltage range of from 10 to 30 VDC is 10 pF Max. of the operating capacity and 2 k Ohm Max. of the operating resistance. |
| Mutual interference | The distance between adjacent antennas is at least 30mm. |
| Permissible operating frequency (Mechanically) | 120 operations / 1 minute Max. |
| Insulation resistance |
Between each terminal and non-live-metallic part: 50 MOhm Min. (at 500 VDC Megger) |
| Dielectric strength |
Between each terminal and non-live-metallic part: 1,000 VAC (50/60 Hz for 1 min) |
| Durability (Mechanically) | 10,000,000 operations Min. (No load) * When operate the actuator with the specified value of the Over Travel. |
| Shock resistance (Destruction) | 1,000 m/s2 |
| Degree of protection | IEC60529 (JEM): Equivalent to IP67 |
| Weight |
Approx. 202 g |