บริษัท ทริปเปิ้ล อี เทรดดิ้ง จำกัด

KEYENCE IG-028ราคา35000บาท

฿35000.00
KEYENCE IG-028
เหลือ 0 ชิ้น
ซื้อเลย
หยิบลงตะกร้า
  • หมวดหมู่ : stock 3e
  • รหัสสินค้า : 010742

รายละเอียดสินค้า KEYENCE IG-028ราคา35000บาท

Model

IG-028

Operation principle

CCD method

Light source

Wavelength

660 nm (Visible light semiconductor laser)

Laser Class

Class 1 Laser Product (IEC 60825-1, FDA (CDRH) Part 1040.10) *6

Output

62 μW

Pulse duration

48 μs

Mounting distance

0 to 1500 mm 59.06"

Measurement range

28 mm 1.10"

Sampling cycle

980 μs (When the number of times for averaging is set to [hsp]: 490 μs)

Minimum detectable
object*1

High sensitivity mode

ø0.1 mm ø0.003" (Setting distance: 100 mm 3.94")

Standard mode

ø0.2 mm ø0.007" (Setting distance: 50 mm 1.97" or less),
ø0.5 mm ø0.02" (Setting distance: 500 mm 19.68")

Repeatability *2

5 μm 0.20 Mil (Setting distance: 100 mm 3.94")
10 μm 0.39 Mil (Setting distance: 500 mm 19.68")
80 μm 3.15 Mil (Setting distance: 1000 mm 39.37")
140 μm 5.51 Mil (Setting distance: 1500 mm 59.06")

Linearity *3

±0.1 % of F.S. (±28 μm ±1.10 Mil)

Temperature characteristics *4

±0.01 % of F.S./°C (±3 μm ±0.12 Mil/°C)

Operation indicator

Transmitter

Optical axis alignment indicator: Green LED, Power indicator: Green LED

Receiver

Optical axis alignment indicator: Green LED, Position monitor: Dual bar LED (Red, Green)

Environment
resistance

Enclosure rating

IP67

Ambient temperature

-10 to +45°C (14 to 113°F) (No freezing)

Ambient humidity

35 to 85% RH (No condensation)

Ambient light *5

Incandescent lamp: 5000 lux Sunlight: 5000 lux

Vibration resistance

10 to 55 Hz, Double amplitude 1.5 mm 0.06" XYZ each axis: 2 hours

Material

Case

Zinc die-cast (Lower case), PBT (Upper case), Polyarylate (PAR) (Display part), SUS304 (Metallic part)

Lens cover

Glass

Cable

PVC

Supplied item

Transmitter × 1, Receiver × 1, Sensor head cables (2 m 6.56') × 2

Weight (including supplied items)

Approx. 500 g

*1 When the measurement target object is measured at the center position of the setting distance. When the measurement mode is set to the glass edge mode, a glass edge of C0.1 mm 0.003" or more can be detected (Setting distance: 500 mm 19.69").
*2 When the light is shielded by half at the center position of the setting distance. Vibration width when the average number of times is set to 16 and sampling is performed for 30 seconds. (When the analog output is used, the margin of error of analog output is added.)
*3 When the setting distance is 100 mm 3.94" and light is shielded at 50 mm 1.96"position from the receiver. Margin of error to the ideal line.
*4 When the setting distance is 100 mm 3.94" and light is shielded by half at 50 mm 1.96" position from the receiver. 
*5 Excluding when the average number of times is set to [hsp].
*6 The classification for FDA (CDRH) is implemented based on IEC60825-1 in accordance with the requirements of Laser Notice No.50.