บริษัท ทริปเปิ้ล อี เทรดดิ้ง จำกัด

WTB2SC-2P3274 SICK ราคา 6275 บาท

฿6275.00
WTB2SC-2P3274 SICK 1063646
เหลือ 0 ชิ้น
ซื้อเลย
หยิบลงตะกร้า
  • หมวดหมู่ : SICK
  • รหัสสินค้า : 017264

รายละเอียดสินค้า WTB2SC-2P3274 SICK ราคา 6275 บาท

    • Sensor/detection principle Photoelectric proximity sensor, Background suppression
      Dimensions (W x H x D) 7.7 mm x 21.8 mm x 13.5 mm
      Housing design (light emission) Rectangular
      Sensing range max. 4 mm ... 90 mm 1)
      Preset sensing range ≥ 45 mm
      Sensing range 10 mm ... 70 mm 1)
      Type of light Visible red light
      Light source PinPoint LED 2)
      Light spot size (distance) 2.2 mm x 9 mm (45 mm)
      Wave length 640 nm
      Laser class IEC 60825-1 / CDRH 21 CFR 1040.10 & 1040.11
      Adjustment

      Cable

      IO-Link

      Pin 2 configuration External input, Teach-in input, Sender off input, Detection output, logic output
      Special features Line-shaped light spot
      • 1) Object with 90 % reflectance (referred to standard white, DIN 5033)
      • 2) Average service life: 100,000 h at TU = +25 °C.
    • SMART TASK
      Smart Task Logic function
      Logic function

      Direct

      AND

      OR

      WINDOW

      Hysteresis

      Timer function

      Deactivated

      On delay

      Off delay

      ON and OFF delay

      Impulse (one shot)

      Inverter Yes
      Switching frequency

      SIO Direct: 1000 Hz 1) 1)

      SIO Logic: 1000 Hz 2) 2)

      IOL: 900 Hz 3) 3)

      Response time

      SIO Direct: 300 µs ... 450 µs 1)

      SIO Logic: 500 µs ... 600 µs 2)

      IOL: 500 µs ... 900 µs 3)

      Repeat accuracy

      SIO Direct: 150 µs 1)

      SIO Logic: 150 µs 2)

      IOL: 400 µs 3)

      Switching signal QL1 Switching output
      Switching signal QL2 Switching output
      • 1) SIO Direct: sensor operation in standard I/O mode without IO-Link communication and without using internal sensor logic or time parameters (set to “direct”/“deactivated”).
      • 2) SIO Logic: Sensor operation in standard I/O mode without IO-Link communication. Sensor-internal logic or timing parameters plus Automation Functions used.
      • 3) IOL: Sensor operation with full IO-Link communication and usage of logic, timing and Automation Function parameters.
    • FIELDBUS, INDUSTRIAL NETWORK
      Fieldbus integration IO-Link V1.1
      Mode COM 2 (38,4 kBaud)
      Cycle time 2.3 ms
      Process data length 16 Bit
      Process data structure

      Bit 0 = switching signal QL1

      Bit 1 = switching signal QL2

      Bit 2 ... 15 = empty

    • MECHANICS/ELECTRONICS
      Supply voltage 10 V DC ... 30 V DC 1)
      Ripple ≤ 5 Vpp 2)
      Power consumption ≤ 20 mA 3)
      Output type PNP 4)
      Switching mode Light/dark switching 4)
      Switching mode selector Programmable
      Output current Imax. < 50 mA
      Response time < 0.5 ms 5)
      Response time Q/ on Pin 2 300 µs ... 450 µs 5) 6)
      Switching frequency Q on Pin2 1,000 Hz 6) 7)
      Connection type Cable with M8 male connector, 4-pin, 200 mm 8)
      Cable material PVC
      Cable diameter Ø 3 mm
      Circuit protection

      A 9)

      B 10)

      D 11)

      Protection class III
      IO-Link ✔
      Transmission rate COM2
      Housing material ABS/PC
      Plastic
      Optics material Plastic, PMMA
      Enclosure rating IP 67
      Special feature Line-shaped light spot
      Description IO-Link
      Ambient operating temperature –25 °C ... +50 °C
      Ambient storage temperature –40 °C ... +75 °C
      UL File No. NRKH.E181493
      Repeatability Q/ on Pin 2: 150 µs 6)
      • 1) Limit values.
      • 2) May not exceed or fall below Uv tolerances.
      • 3) Without load.
      • 4) Parametrisable via IO-Link.
      • 5) Signal transit time with resistive load.
      • 6) Valid for Q on Pin2, if configured with software.
      • 7) With light/dark ratio 1:1.
      • 8) Do not bend below 0 °C.
      • 9) A = VS connections reverse-polarity protected.
      • 10) B = output reverse-polarity protected.
      • 11) D = outputs overcurrent and short-circuit protected.