FunctionsFixed blanking with 1-beam tolerance, MaxiScan, Integration of “electronic safety-related switching outputs”, Reduced resolution, can be changed to “fixed blanking” during operation, Fixed blanking without tolerance, Transmission channel changeover, Start/restart interlock (RES), Combination of floating/fixed blanking, can be changed to “fixed blanking” during operation, Fixed blanking without tolerance, can be activated/deactivated during operation, Partial muting, Integration of “contact-based safety circuit”, Contactor monitoring (EDM), Muting-timeout extension, Timing controlled 2-sensor muting, Floating blanking, can be changed to “fixed blanking” during operation
Characteristic parameters
Type4, IEC/EN 61496
SIL3, IEC 61508
SILCL3, IEC/EN 62061
Performance Level (PL)e, EN ISO 13849-1
PFHD7.73E-09 per hour
Mission time20 years, EN ISO 13849-1
Category4, EN ISO 13849
Protective field data
Resolution14 mm
Protective field height750 mm
Optical data
SynchronizationOptical between transmitter and receiver