บริษัท ทริปเปิ้ล อี เทรดดิ้ง จำกัด

Fluke 87V/IMSK Industrial Multimeter Service KIT with the i400 ราคา 21,829 บาท

฿21829.00
Fluke 87V/IMSK Industrial Multimeter Service KIT with the i400 ราคา 21,829 บาท
เหลือ 0 ชิ้น
ซื้อเลย
หยิบลงตะกร้า
  • หมวดหมู่ : FLUKE
  • รหัสสินค้า : 065047

รายละเอียดสินค้า Fluke 87V/IMSK Industrial Multimeter Service KIT with the i400 ราคา 21,829 บาท

Fluke 87V/IMSK Specifications

Electrical Specifications
DC VoltageRange: 0.1 mV to 1000 V
Accuracy: ±(0.05% + 1)
Maximum resolution: 10 µV
AC VoltageRange: 0.1 mV to 1000 V
Accuracy: ±(0.7% + 2) True RMS
AC bandwidth: 20 kHz with low pass filter; 3 dB @ 1 kHz
Maximum resolution: 0.1 mV
DC CurrentRange: 0.1 µA to 10 A (20 A for 30 seconds maximum)
Amps Accuracy: ±(0.2% + 2)
Maximum resolution: 0.01 µA
AC CurrentRange: 0.1 µA to 10 A (20 A for 30 seconds maximum)
Amps Accuracy: ±(1.0% + 2) True RMS
Maximum resolution: 0.1 µA
ResistanceRange: 0.1 Ω to 50 MΩ
Accuracy: ±(0.2% + 1)
Maximum resolution: 00.1 Ω
CapacitanceRange: 1 nF to 9999µF
Accuracy: ±(1% + 2)
Maximum resolution: 0.01 nF
FrequencyRange: 0.5 Hz to 199.99 kHz
Accuracy: ±(0.005% + 1)
Maximum resolution: 0.01 Hz
Duty CycleRange: 99.9%
Accuracy: ±(0.2% per kHz + 0.1%)
Maximum resolution: 0.1%
Temperature Measurements–328 to 1994°F (–200 to 1090°C) excluding probe
80 BK Temperature Probe–40 to 500°F, ± 4.0°F or 2% (–40.0 to 260°C, ± 2.2°C or 2%) whichever is greater
ConductanceMaximum conductance: 60.00 nS
Accuracy: ±(1.0% + 10)
Maximum resolution: 0.01 nS
DiodeRange: 3 V
Resolution: 1 mV
Accuracy: ±(2% + 1)
Duty Cycle RangeAccuracy: within ±(0.2% per kHz + 0.1%)
Data StoragePeak transient capture: 250µS
Min/Max/Avg: Yes
Reading hold: Yes
DisplayDigital: 6000 counts updates 4/sec, 19,999 counts in high–resolution mode
Analog bar graph: 32 segments, updates 40/sec
Backlight: Yes
Frequency: 19,999 counts, updates 3/sec at >10 Hz
Low Pass FilterMeasurement of VFDs: Yes
Environmental Specifications
Operating Temperature-4 to 131°F (–20 to 55°C)
Storage Temperature-40 to 140°F (–40 to 60°C)
Humidity (Without Condensation)0 to 90% at 32 to 95°F (0 to 35°C)
0 to 70% at 95 to 131°F (35 to 55°C)
Operating Altitude6561.68' (2000 m)
Mechanical and General Specifications
IP Rating30
Shock3.3' (1 m) drop per
VibrationPer MIL–PRF–28800 for a Class 2 instrument
Power3 x AA batteries, 400 hours typical without backlight
Dimensions7.9 x 3.9 x 2" (201 x 98 x 52 mm)
Weight0.8 lb (355 g)
Safety Specifications
ComplianceCAT IV 600 V , CAT III 1000 V
Overvoltage CategoryEN 61010–1 to 1000 V CAT III, 600V CAT IV
Agency ApprovalsCE, CSA