TRIPLE E TRADING CO., LTD.
Fluke 124 Industrial ScopeMeter Model Fluke 124/003S
฿81860.00
Includes: <br>
Fluke 124 Industrial ScopeMeter Model# Fluke 124/003S; <br>
AC120 Alligator clips; <br>
BB120 Shielded BNC adapter;
เหลือ 99 ชิ้น
ซื้อเลย
หยิบลงตะกร้า
  • หมวดหมู่ : Scope Meters \quot;Oscilloscopes\quot;
  • รหัสสินค้า : 006946

รายละเอียดสินค้า Fluke 124 Industrial ScopeMeter Model Fluke 124/003S

 

Specifications
Oscilloscope Bandwidth Fluke 124: 40 MHz
Dual input True RMS Meter Vdc, Vac, Vac+Vdc, Ohms,Continuity , Diode-test
Current, °C, °F, Capacitance, dBV, dBM, Crest Factor, Touch Hold and Zeroset
TrendPlot Recording Automatic vertical scaling and time compression.
Display the actual, MIN, MAX and AVG reading.
Cursors Fluke 124: ∆T, 1/∆T, V, ∆V, rise- and fall time
Real-time sample rate 25 MS/s
Equivalent sampling rate up to 2.5 GS/s (125, 124) or 1.25 GS/s (123).
Inputs and digitizers 2
Timebase range Fluke 124: 20 ns - 1 min/div
Input sensitivity 5 mV - 500 V/div
Trigger types Connect-and-View™, Free Run, Single Shot, Edge, Video, External
Glitch capture 40 ns
Scope measurements Automatic measurements: 26 (all instruments) On top, Fluke 124 has additional measurement functions for Power (W), VA, VAR and Power Factor (PF) for single phase and balanced-three-phase (delta) power systems.
Harmonics mode Fluke 124 has capbility to analyze the harmonics contents of power signals. See below for details.
Maximum record length 512 min/max pts per input
Memory Fluke 124: 20 screens and setups
Additional Power measurement capabilities (Fluke 125 only)
Measurement types
  • Watt,
  • VA,
  • VAR,
  • Power Factor (PF)
Power configuration Single phase or balanced three-phase (delta-configuration) mains supply
Voltage measurement Channel A; using STL120, voltage probe or direct input
Current measurement Channel B, using i400s (included) or other compatible current clamp
Current Clamp or Shunt sensitivity 0.1 / 1 / 10 / 100 / 1000 mV/A, 10 mV/mA and 400 mV/A.
Harmonics Mode (Fluke 125 only)
  Converts waveform information into a harmonics display (using FFT processing) which shows the relative amplitudes of the 1st up to the 33rd harmonic
Analyzed waveform Voltage waveform(Ch.A), Current wavefrom (Ch.B) or Power (Ch.A x Ch.B), automatically generated.
Harmonics Frequency range DC up to 33rd harmonic (for fundamental up to 60 Hz);
DC up to 24th harmonic (for fundamental up to 400 Hz).
Display Bargraph showing 1st up to 33rd harmonic and DC; amplitude displayed in % relative to fundamental
Measurements Relative amplitude of individual harmonics;
THD in %r or %f.
Environmental Specifications
Operating Temperature 0 ºC to 50 ºC
Storage Temperature -20 °C to +60 °C
Operating Altitude 3,000 m
Safety Specifications
Electrical Safety 600V CAT III (EN61010-1)
Mechanical & General Specifications
Size 232 x 115 x 50 mm
Weight 1.2 kg
Wartanty 3-years on main instrument, 1-year on accessories
Battery Life 7 hrs using NiMH
RS232/USB Interface Optically isolated via optional PM9080 or OC4USB for interfacing to Printer or PC

สินค้าที่เกี่ยวข้อง Fluke 124 Industrial ScopeMeter Model Fluke 124/003S