| Specifications | |
| Oscilloscope Bandwidth | Fluke 124: 40 MHz |
| Dual input True RMS Meter |
Vdc, Vac, Vac+Vdc, Ohms,Continuity , Diode-test Current, °C, °F, Capacitance, dBV, dBM, Crest Factor, Touch Hold and Zeroset |
| TrendPlot Recording |
Automatic vertical scaling and time compression. Display the actual, MIN, MAX and AVG reading. |
| Cursors | Fluke 124: ∆T, 1/∆T, V, ∆V, rise- and fall time |
| Real-time sample rate | 25 MS/s |
| Equivalent sampling rate | up to 2.5 GS/s (125, 124) or 1.25 GS/s (123). |
| Inputs and digitizers | 2 |
| Timebase range | Fluke 124: 20 ns - 1 min/div |
| Input sensitivity | 5 mV - 500 V/div |
| Trigger types | Connect-and-View™, Free Run, Single Shot, Edge, Video, External |
| Glitch capture | 40 ns |
| Scope measurements | Automatic measurements: 26 (all instruments) On top, Fluke 124 has additional measurement functions for Power (W), VA, VAR and Power Factor (PF) for single phase and balanced-three-phase (delta) power systems. |
| Harmonics mode | Fluke 124 has capbility to analyze the harmonics contents of power signals. See below for details. |
| Maximum record length | 512 min/max pts per input |
| Memory | Fluke 124: 20 screens and setups |
| Additional Power measurement capabilities (Fluke 125 only) | |
| Measurement types |
|
| Power configuration | Single phase or balanced three-phase (delta-configuration) mains supply |
| Voltage measurement | Channel A; using STL120, voltage probe or direct input |
| Current measurement | Channel B, using i400s (included) or other compatible current clamp |
| Current Clamp or Shunt sensitivity | 0.1 / 1 / 10 / 100 / 1000 mV/A, 10 mV/mA and 400 mV/A. |
| Harmonics Mode (Fluke 125 only) | |
| Converts waveform information into a harmonics display (using FFT processing) which shows the relative amplitudes of the 1st up to the 33rd harmonic | |
| Analyzed waveform | Voltage waveform(Ch.A), Current wavefrom (Ch.B) or Power (Ch.A x Ch.B), automatically generated. |
| Harmonics Frequency range |
DC up to 33rd harmonic (for fundamental up to 60 Hz); DC up to 24th harmonic (for fundamental up to 400 Hz). |
| Display | Bargraph showing 1st up to 33rd harmonic and DC; amplitude displayed in % relative to fundamental |
| Measurements |
Relative amplitude of individual harmonics; THD in %r or %f. |
| Environmental Specifications | |
| Operating Temperature | 0 ºC to 50 ºC |
| Storage Temperature | -20 °C to +60 °C |
| Operating Altitude | 3,000 m |
| Safety Specifications | |
| Electrical Safety | 600V CAT III (EN61010-1) |
| Mechanical & General Specifications | |
| Size | 232 x 115 x 50 mm |
| Weight | 1.2 kg |
| Wartanty | 3-years on main instrument, 1-year on accessories |
| Battery Life | 7 hrs using NiMH |
| RS232/USB Interface | Optically isolated via optional PM9080 or OC4USB for interfacing to Printer or PC |