Specifications | |
Oscilloscope Bandwidth | Fluke 125: 40 MHz |
Dual input True RMS Meter |
Vdc, Vac, Vac+Vdc, Ohms,Continuity , Diode-test Current, °C, °F, Capacitance, dBV, dBM, Crest Factor, Touch Hold and Zeroset |
TrendPlot Recording |
Automatic vertical scaling and time compression. Display the actual, MIN, MAX and AVG reading. |
Cursors | Fluke 125: ∆T, 1/∆T, V, ∆V, rise- and fall time |
Real-time sample rate | 25 MS/s |
Equivalent sampling rate | up to 2.5 GS/s (125, 124) or 1.25 GS/s (123). |
Inputs and digitizers | 2 |
Timebase range | Fluke 125: 20 ns - 1 min/div |
Input sensitivity | 5 mV - 500 V/div |
Trigger types | Connect-and-View™, Free Run, Single Shot, Edge, Video, External |
Glitch capture | 40 ns |
Scope measurements | Automatic measurements: 26 (all instruments) On top, Fluke 125 has additional measurement functions for Power (W), VA, VAR and Power Factor (PF) for single phase and balanced-three-phase (delta) power systems. |
Harmonics mode | Fluke 125 has capbility to analyze the harmonics contents of power signals. See below for details. |
Maximum record length | 512 min/max pts per input |
Memory | Fluke 125: 20 screens and setups |
Additional Power measurement capabilities (Fluke 125 only) | |
Measurement types |
|
Power configuration | Single phase or balanced three-phase (delta-configuration) mains supply |
Voltage measurement | Channel A; using STL120, voltage probe or direct input |
Current measurement | Channel B, using i400s (included) or other compatible current clamp |
Current Clamp or Shunt sensitivity | 0.1 / 1 / 10 / 100 / 1000 mV/A, 10 mV/mA and 400 mV/A. |
Harmonics Mode (Fluke 125 only) | |
Converts waveform information into a harmonics display (using FFT processing) which shows the relative amplitudes of the 1st up to the 33rd harmonic | |
Analyzed waveform | Voltage waveform(Ch.A), Current wavefrom (Ch.B) or Power (Ch.A x Ch.B), automatically generated. |
Harmonics Frequency range |
DC up to 33rd harmonic (for fundamental up to 60 Hz); DC up to 24th harmonic (for fundamental up to 400 Hz). |
Display | Bargraph showing 1st up to 33rd harmonic and DC; amplitude displayed in % relative to fundamental |
Measurements |
Relative amplitude of individual harmonics; THD in %r or %f. |
Environmental Specifications | |
Operating Temperature | 0 ºC to 50 ºC |
Storage Temperature | -20 °C to +60 °C |
Operating Altitude | 3,000 m |
Safety Specifications | |
Electrical Safety | 600V CAT III (EN61010-1) |
Mechanical & General Specifications | |
Size | 232 x 115 x 50 mm |
Weight | 1.2 kg |
Wartanty | 3-years on main instrument, 1-year on accessories |
Battery Life | 7 hrs using NiMH |
RS232/USB Interface | Optically isolated via optional PM9080 or OC4USB for interfacing to Printer or PC |
This website uses cookies (Learn more) and has a privacy policy (Learn more).