Accuracy of
operating time |
±0.2% FS max. (±0.2%±10 ms max. in a range of 1.2 s or 3 s) |
|
Setting error |
±5% FS ±50 ms *1 |
|
Reset time |
Min. power-opening time: 0.1 s max.
Min. pulse width: 0.05 s (H3CR-A/-AS) |
|
Reset voltage |
10% max. of rated supply voltage |
|
Influence of voltage |
±0.2% FS max. (±0.2%±10 ms max. in a range of 1.2 s or 3 s) |
Influence of
temperature |
±1% FS max. (±1%±10 ms max. in a range of 1.2 s or 3 s) |
|
Insulation resistance |
100 MΩ min. (at 500 VDC) |
|
Dielectric strength |
2,000 VAC (1,000 VAC for H3CR-A[]S), 50/60 Hz for 1 min (between current-carrying metal parts and exposed non-current-carrying metal parts)
2,000 VAC (1,000 VAC for H3CR-A[]S), 50/60 Hz for 1 min (between control output terminals and operating circuit)
2,000 VAC, 50/60 Hz for 1 min (between contacts of different polarities)
1,000 VAC, 50/60 Hz for 1 min (between contacts not located next to each other)
2,000 VAC, 50/60 Hz for 1 min (between input and control output terminals and operation circuit) for H3CR-AP |
Impulse withstand
voltage |
3 kV (between power terminals) for 100 to 240 VAC/100 to 125 VDC, 1 kV for 24 to 48 VAC/12 to 48 VDC
4.5 kV (between current-carrying terminal and exposed non-current-carrying metal parts) for 100 to 240 VAC/100 to 125 VDC, 1.5 kV for 24 to 48 VAC/12 to 48 VDC and 24 to 48 VAC/VDC |
|
Noise immunity |
±1.5 kV (between power terminals) and ±600 V (between no-voltage input terminals), square-wave noise by noise simulator (pulse width: 100 ns/1 μs, 1-ns rise) |
|
Static immunity |
Malfunction: 8 kV
Destruction: 15 kV |
|
Vibration resistance |
Destruction: 10 to 55 Hz with 0.75-mm single amplitude each in 3 directions for 2 hours each
Malfunction: 10 to 55 Hz with 0.5-mm single amplitude each in 3 directions for 10 minutes each |
|
Shock resistance |
Destruction: 1,000 m/s2 3 times each in 6 directions
Malfunction: 100 m/s2 3 times each in 6 directions |
|
Ambient temperature |
Operating: -10°C to 55°C (with no icing)
Storage: -25°C to 65°C (with no icing) |
|
Ambient humidity |
Operating: 35% to 85% |
|
Life expectancy |
Mechanical: 20,000,000 operations min. (under no load at 1,800 operations/h)
Electrical: 100,000 operations min. (5 A at 250 VAC, resistive load at 1,800 operations/h) *2 |
|
EMC |
(EMI): EN61812-1
Emission Enclosure: EN55011 Group 1 class A
Emission AC Mains: EN55011 Group 1 class A
(EMS): EN61812-1
Immunity ESD: IEC61000-4-2: 6 kV contact discharge (level 3), 8 kV air discharge (level 3)
Immunity RF-interference from AM Radio Waves: IEC61000-4-3: 10 V/m (80 MHz to 1 GHz) (level 3)
Immunity RF-interference from Pulse-modulated Radio Waves: IEC61000-4-3: 10 V/m (900±5 MHz) (level 3)
Immunity Conducted Disturbance: IEC61000-4-6: 10 V (0.15 to 80 MHz) (level 3)
Immunity Burst: IEC61000-4-4: 2 kV power-line (level 3), 2 kV I/O signal-line (level 4)
Immunity Surge: IEC61000-4-5: 1 kV line to line (level 3), 2 kV line to ground (level 3) |
|
Case color |
Light gray (Munsell 5Y7/1) |
|
Degree of protection |
IP40 (panel surface) |
|
Weight |
Approx. 90 g |